SCHMIDT® Technology has developed a high temperature version of the SS 20.60 for the applica-tion in operating temperature up to 350 °C - for short time even 400 °C.
The sensor differs formally in the white ceramic tip. Most of the modifications have been made in-side the sensor and the modules are designed according to the elevated specification.
A complete new designed electronic unit processes the results of measurement and provides a digital and analogue output of flow velocity as well as temperature. The new status indicator dis-plays information about the current flow velocity and the sensors status. Due to the modular con-cept the unit can also be supplied with field bus interfaces. The sensors with field bus interfaces can calculate Kg/hr or m³/min and thus disburdens the supervising PLC. Additionally the sensor gives access to its status information and allows the PLC to inform the user about defects of the sensor.
Applications:
Mass flow-control of combustion processes, burner control, flow measurement of process gases, volume flow measurement of test stands, Measurement of flow velocity in drying plants and steril-izing processes.
Technical data:
Design:
Immersion sensor with integrated transducer
Application:
Free air and guided air in ducts from 25 to 1.000 mm
Measuring range:
0.2 … 20 m/s
Pressure
atmospheric
Temperature
0 ... 350 °C
Mounting:
G ½ thread
Analogue output:
0...10V, 0/4 ... 20 mA
Digital output Impulse or switching (10 to 100 Hz)
Power supply:
24 VDC / approx. 150 mA
Field bus version:
Profibus DP, Device Net.